Product Name: |
SLK-3051 oil gas chemical Pressure Transmitter
|
Supply Ability: |
1000pieces |
Related proudcts |
chemical, pressure transmitter, oil gas, |
Specifications |
6KG |
Price Term: |
FOB |
Port of loading: |
Shenzhen |
Minimum Order |
1 piece |
Unit Price: |
USD230-260 |
|
Application
Widely used in pharmaceutical, medical equipment, oil, gas, chemical, urban construction power, metallurgy, textile, aero***ce, scientific research, leak ***ection, automation equipment and other fields.
Technical Data
Measuring medium
liquid, gas, air
Measuring range
Range 3 0-1.3~7.5kPa
Range 4 0-6.2~37.4kPa
Range 5 0-31~186.8kPa
Range 6 0-117~690kPa
Range 7 0-345~2068kPa
Range 8 0-1170~6890kPa
Range 9 0-3480~20680kPa
Range 0 0-6890~41370kPa
Accuracy
¡À0.1% URL ¡À0.2% URL
Signal output
4~20mA 4~20mA with HART
Supply voltage
24VDC(12VDC~45VDC) Explosion-proof type:12~28VDC
Stability
¡À0.1 URL in six months
Medium temperature
-40~+100℃
Storage temperature
-40~+100℃(without LCD display) -40~+70℃(with LCD display)
Operating temperature
-40~+85℃(without LCD display) -30~+60℃(with LCD display)
Ambient temperature
-0~-100% relative humidity
Temperature i***ct
¡À(0.2%URL+0.18%inspection range)/56℃
Power supply effect
Less than 0.0059% / V of the output range
Load effect
No load is affected unless the supply voltage changes
Vibration effect
The vibration effect is ¡À 0.05% URL / g at 200 Hz in any axial direction.
EMI/RFI effect
Between 20 to 1000MHz;field strength up to 30V / M; the output drift less than ¡À 0.1% range;
Installation site effect
Maximum Zero drift is ¡À 0.25kPa; all zero drift can be corrected.
Zero point positive and negative migration
When zero is moving, the minimum range must be larger than or equal to - URL, the maximum range must be less than or equal to + URL. The calibration range must be greater than or equal to the minimum range.
Zero and range
Zero and range can be adjusted with the instrument range and zero button, or with the HART handhold remote adjustment.
Static pressure and over-pressure limit
Transmitter on any side plus 0 to 13.79*** pressure will not cause damage. In the 0kPa to the tra |